Fyre Stop Systems

FyreCOLLAR Cast-In High Top Fire Collars

Home / All Categories / Product Ranges / Fire Collar Systems / FyreCOLLAR Cast-In High Top Fire Collars

Description

Trafalgar’s Australian Made FyreCOLLAR Cast-in High Top range of fire collars provides a full range of solutions for use in both stack pipe and floor waste applications, with up to 4 hours across a huge range of common pipe types and sizes.  Specifically for stack and plumbing pipes, locally made, injection moulded and designed to be cast directly into concrete floor slabs for the provision of plastic pipe penetrations without the need to pre-install sections of pipework, decreasing the amount of time spent on site.

These collars are designed for use in concrete floor slabs up to 250mm thick, where the head of the high cast-in fire collar extends above the surface of the floor so that sections of pipe are not needed as part of the installation process. Once the concrete is set, simply run your plastic or metal pipes through the collars which are fitted with a rubber gasket to prevent smoke leakage through the penetration.

The high-top cast-in fire collars are available in three sizes each suitable for a range of pipe sizes:

  • 40mm – 65mm for 40mm, 50mm and 65mm pipes
  • 80mm – 100mm for 80mm and 100mm pipes

Key Features

  • Pipes: PVC, HDPE, PP-R, PP, RAUPIANO
  • Polypropylene body material gives high moisture resistance and flexural strength
  • The high-grade intumescent formulation for fire performance
  • Suitable for slabs up to 250mm
  • High profile design saves time on site
  • Rubber seal to stop water/debris
  • Plastic cap included for protection during installation
  • Flexible rubber membrane absorbs pipe movement and vibration
  • Now approved for copper and steel pipes up to 100mm diameter with TWRAP™ and UniGUARD™ installed on the top side of the slab to protect against heat
    transfer through the metal pipe.
  • Fire tested with collar flanges located directly next (but not overlapping) adjacent walls, to ensure activation in tight spaces
  • Collars fire tested directly next to each other with flanges overlapping for tight spaces
  • The FyreCOLLAR Cast-In High range is also fire tested for up to 2 x pair coil bundles with FR insulation and associated cables. This covers -/240/90 wrap free, refer to the approvals in the Technical Manual for further details.

 

Cast In Collar High Top Sizes Available:

  • 40mm – 65mm for 40mm, 50mm and 65mm pipes
  • 80mm – 100mm for 80mm and 100mm pipes

For more about fire collars read this article 

Learn More about the difference between STACK and FLOOR-WASTE Fire Collars

 

Test Reports and Documents:

 

FAQs

No, this runs the risk of the collar plastic melting in a fire and the back-filled concrete slipping out. FyreBOARD Maxilite® can be used, refer to the Technical Manual.

Collars can cover a range of sizes as specified on page 17 of the Technical Manual. Otherwise, the pipe must be the correct size per the approvals tables in this manual. If you have already run a smaller pipe than what is approved, refer to page 16 of the Technical Manual.

The advantage of the high-cast collar is that no pipe formers need to be used when pouring the slab. This is required for the low-cast collar however it is sometimes preferable to use a low-profile collar.

The flange of the collar can overlap other Trafalgar Cast-in collars by at most 20mm. FRL is limited to -/120/120 (otherwise collars should be 50mm apart). Refer to page 19 of the Technical Manual.

 

In Stock

FyreCOLLAR Cast-In

2 Videos

FyreCOLLAR Cast-In Stack High Collar Technical Manual

Download

FyreCOLLAR Cast- In Assessment Report FCO-3475

Download

FyreCOLLAR Range BIM Models

Download

FyrePLATE Data Sheet

Download

Article - Fire Collars: Are They As Simple As Many Think?

Download

Article - The history of Fire Collars

Download

Blog - Understanding Different Fire Collars: Stack V/S Floor Waste Applications

Download

For more information, please contact our Technical Team at [email protected] or 1800 888 714.