FYRE STOP SYSTEMS

FyreBOARD Maxilite® Fire Rated Board- Fire Damper Upgrades

Home / All Categories / Product Ranges / FyreBOARD Systems / FyreBOARD Maxilite® Fire Rated Board- Fire Damper Upgrades

Description

Often fire dampers are installed into openings that are too large to install correctly, so FyreBOARD Maxilite® has been approved for use to pack out the gaps around mechanical and intumescent fire dampers in walls and floors, in accordance with AS1530.4-2014. Please review the technical manual for a full list of specific system FRL’s and installation requirements.

Due to the lightweight construction of the board, Maxilite is easy to handle and work with, ensuring quick onsite installation, whilst retaining suitable fire performance. Maxilite’s high fire performance ensures minimal thicknesses are required, hence less material usage and cost. Stable under high temperatures whilst being crack-free, Maxilite is perfectly suited for upgrading existing fire dampers.

FyreBOARD Maxilite Applications:

FyreBOARD Maxilite® offers a comprehensive board solution for closing down large openings around service penetrations for electrical, mechanical and plumbing services and has been approved for fire ratings of up to 240mins (service dependent) to AS1530.4-2014. Maxilite is used as a full system with a combination of FyreFLEX Sealant, TWrap, the retrofit FyreCOLLAR range, and certain size FyreBOX’s. Please review the technical manual for a full list of specific system FRLs and installation requirements.  

Download the Technical Manual here

FyreBOARD Maxilite® is a thin, lightweight, high-performance fire-resistant board that is suited to various applications. Maxilite is stable under high temperatures which makes it the perfect solution for constructing fire-rated bulkheads, ceilings, and enclosures and provides fire compartmentation around building services and is approved to AS1530.4-2014. Please review the technical manual for a full list of specific system FRL’s and installation requirements.

Download the Technical Manual here

Often fire dampers are installed into openings that are too large to install correctly, so FyreBOARD Maxilite® has been approved for use to pack out the gaps around mechanical and intumescent fire dampers in walls and floors, in accordance with AS1530.4-2014. Please review the technical manual for a full list of specific system FRL’s and installation requirements.  

Download the Technical Manual here

FyreBOARD Maxilite® is a lightweight high performance fire rated board available in 30mm, 40mm and 60mm thicknesses for use in fire protection for a large range of structural steel sizes and types for up to 4 hours of protection. FyreBOARD Maxilite® has been tested to various international test standards as well as AS1530.4, with  complete regression analysis that complies with AS4100 as appropriate for steel protection under Schedule 5 of the NCC. Please review the Structural Steel technical manual to look up your steel section/size to find what thickness of board is needed for your next project.

Download the Technical Manual here

Where concrete slabs, walls or beams are poured too thin or don’t have enough cover over reo-bars to comply with AS3600 requirements for fire design, FyreBOARD Maxilite® provides a lightweight board option that is perfect for upgrading these non-compliant concrete structures, without adding lots of weight compared with spray and plasterboard systems. FyreBOARD Maxilite® is a lightweight high-performance fire rated board available in 30mm, 40mm and 60mm thicknesses and as an added benefit is compatible with approved service penetrations without any fire-engineered solutions required. Contact the technical team for more information on this application at [email protected]

FyreBOARD Maxilite® has been approved for use as a compliant penetration system to fix to the soffit of a concrete slab to protect services that feed into floor mounted switch boxes, such are commonplace in board-rooms and schools. This system also provides a compliant system to seal PVC conduits that are cast-into the concrete floor and exit at through soffit of the slab. Services that pass through the FyreBOARD Maxilite® in this configuration can be sealed with FyreFLEX® sealant (for cables) and continuous PVC conduits may be treated by installing a retrofit FyreCOLLAR fixed into the FyreBOARD Maxilite® as shown in the installation drawings in the below technical manual.  

Download the Technical Manual here

FyreBOARD Maxilite MSDS

Download

FyreBOARD Maxilite: Damper Installation Approval for Walls and Floors Test Report

Download

FyreBOARD Maxilite Fire Damper Upgrades Technical Manual

Download

Article - Passive Fire Protection of Steel Structures

Download

Article - Fire Rated Board Systems

Download

For more information, please contact our Technical Team at [email protected] or 1800 888 714.