FYRE STOP SYSTEMS

Siderise® CWFS

Description

The primary function of Siderise® CWFS (Curtain Wall Fire Stopping) system is to provide a continuous perimeter fire, smoke and acoustic seal by sealing the void between compartment floors and walls and the external building envelope.

Siderise® CWFS is a foiled stone wool cavity barrier system engineered specifically to handle building movement whilst maintaining the fire, smoke and acoustic seals. Siderise® CWFS systems utilise a unique method of manufacture that provides a well identifiable, ready to use product that is resilient in lateral compression. The factory-manufactured material facilitates fast, clean and easy installation, ensuring a requisite tight fit and enhances fire, smoke and sound integrity.

Siderise® CWFS systems have been fire tested and approved to AS1530 Part 4 as well as European fire test method for an FRL of -/120/120 and can accommodate void widths up to 600mm wide. Additional AS1530.4 fire testing has been conducted for CLT construction achieving an FRL of -/60/60.

Key Features:

  • Engineered factory made system
  • Market leading fire resistance and smoke seals
  • Unique systems providing ability to accommodate façade movement
  • Simple and quick installation
  • AS1530 Part 4 fire testing
  • Complies with NCC C2.6
  • Backed by Trafalgar technical support
  • Small brackets at 600mm centres only
  • Non-combustible

 

Applications:

NCC requires the use of cavity barriers in Clause C1.13 and Specification C1.13

Siderise cavity barriers have been fire tested to both AS1530 Part 4 – 2014 and provide the NCC required fire ratings for Fire Protected Timber – Cross Laminated Timber (CLT) construction. 

The fast, clean and easy Siderise systems exceed the requirements of NCC and allow for proven fire performance in CLT construction.

Key Features

  • Market leading fire resistance and smoke seal
  • Suitable for both horizontal and vertical cavity barriers
  • Suitable also for protection of window and door openings
  • Unique product construction provides the ability to accommodate facade movement
  • Fully qualified acoustic performance
  • Simple and quick to install

 Download the Siderise fire test to AS1530 Part 4 for both CLT and standard timber construction barriers here.

SIDERISE EW Fibre Cement external wall facade systems have been developed to provide a simple and easy to install method of providing a fire, smoke or acoustic seals at the slab edge.

This includes; Exotec, Equitone, Cemintel and Fiberclad proprietary facade systems.

These products are a closed state, friction fit system used where no ventilation or drainage of the cavity is required. Where ventilation and drainage is required please refer to our Rainscreen Cladding Systems 

EW-FS120 is for use as a Fire Stop in accordance with the NCC or BCA.

Additionally, the products have excellent sound reduction qualities which can be used to combat unwanted noise via flanking transmission.

Key Features

  • Fire resistance: up to 2 hours
  • Sound reduction: up to 25dB (Rw)
  • Integral smoke barrier
  • Independent movement testing to withstand thermal expansion and structural movement.
  • Certifire 3rd Party Approval

Siderise CWFS (Curtain Wall Fire Stop) systems are a proven means to protect the slab edge perimeter behind a glazed curtain wall for spread of fire, smoke and sound.

The fast, clean and easy systems provides guaranteed movement capabilities, meeting NCC requirement for structural and thermal building movement in C2.6

Key Features

  • Market leading fire resistance and smoke seal
  • Suitable for horizontal and vertical application
  • Unique product construction provides ability to accommodate facade movement
  • fully qualified acoustic performance
  • Simple and quick to install

SIDERISE EW Hebel and Walsc AAC external wall facade systems have been developed to provide a simple and easy to install method of providing a fire, smoke or acoustic seals at the slab edge.

These products are a closed state, friction fit system used where no ventilation or drainage of the cavity is required. Where ventilation and drainage is required please refer to our Rainscreen Cladding Systems 

EW-FS120 is for use as a Fire Stop in accordance with the NCC or BCA.

Additionally, the products have excellent sound reduction qualities which can be used to combat unwanted noise via flanking transmission.

Key Features

  • Fire resistance: up to 2 hours
  • Sound reduction: up to 25dB (Rw)
  • Integral smoke barrier
  • Independent movement testing to withstand thermal expansion and structural movement.
  • Certifire 3rd Party Approval

SIDERISE EW masonry external wall facade systems have been developed to provide a simple and easy to install method of providing a fire, smoke or acoustic seals at the slab edge.

These products are a closed state, friction fit system used where no ventilation or drainage of the cavity is required. Where ventilation and drainage is required please refer to our Rainscreen Cladding Systems 

EW-FS120 is for use as a Fire Stop in accordance with the NCC or BCA.

Additionally, the products have excellent sound reduction qualities which can be used to combat unwanted noise via flanking transmission.

Key Features

  • Fire resistance: up to 2 hours
  • Sound reduction: up to 25dB (Rw)
  • Integral smoke barrier
  • Independent movement testing to withstand thermal expansion and structural movement.
  • Certifire 3rd Party Approval

Siderise CWFS Technical Manual

Download

Siderise Fire Test Report - AS1530.4 for CLT and Standard Timber Construction Barriers

Download

AS1530.4 Test Report

Download

Siderise CWFS MSDS

Download

AS1530.1 Test Report

Download

AS1530.3 Test Report

Download

Clear

For more information, please contact our Technical Team at [email protected] or 1800 888 714.