WATER TIGHT CURTAIN WALL
The primary function of Siderise® CWFS (Curtain Wall Fire Stopping) system is to provide a continuous perimeter fire, smoke and acoustic seal by filling the void between internal compartment floors and walls and the external curtain wall. Siderise CWFS is perfect for AS4284 watertight façades.
CURTAIN WALL
The primary function of Siderise® CWFS (Curtain Wall Fire Stopping) system is to provide a continuous perimeter fire, smoke and acoustic seal by sealing the void between compartment floors and walls and the external building envelope.
CURTAIN WALL
The primary function of Siderise® CWFS (Curtain Wall Fire Stopping) system is to provide a continuous perimeter fire, smoke and acoustic seal by sealing the void between compartment floors and walls and the external building envelope.
Does your cavity barrier have to allow for ventilation?
If your cavity barrier has to allow for ventilation, then use the link below to go to our Rainscreen Cladding page.
Horizontal Cavities behind Rainscreen Cladding must be open-state. Open-state cavity barriers allow ventilation within a cavity under cold (normal) conditions and close the cavity under fire conditions. Such cavity barriers commonly comprise intumescent materials that can be activated at elevated temperatures (typically about 180 – 200°C). The intumescent materials continuously expand and seal the cavity gaps whilst remaining in place and withstanding the fire conditions for a considerable period.
Both horizontal and vertical cavity barriers behind watertight curtain walls are closed state. The Siderise CWFS (Curtain Wall Fire Stop) cavity barrier is simple to use and can be easily cut to the correct size on site to suit the cavity width. This system utilises simple mounting brackets spaced at 600mm centres.
Frequently Asked Questions
At Trafalgar Fire, we’re dedicated to making passive fire easier for you. To save you some time, we’ve answered a collection of Frequently Asked Questions about Cavity Barriers applications.
If you have any additional questions, our Technical Team is here to help.
TWRAP™ (or FyreWrap®) will need to be wrapped around the FyreBOX™ to achieve an insulation rating. Contact Trafalgar Fire for installation details and refer to our YouTube channel for installation videos.
Yes, refer to the FyrePEX HP Technical Manual for details on approved cables.
Yes, intumescent sealants require the perfect volume of sealant to expand and perform appropriately.
Using FyreSHEATH removes the need for larger openings.