Fyre Stop Systems

FyreBATT 50 | Fire-Rated Batt Penetration System for Structural Penetrations

Home / All Categories / Product Ranges / Ryanfire / FyreBATT 50 | Fire-Rated Batt Penetration System for Structural Penetrations

Description

Trafalgar FyreBATT 50 (also known as Ryanbatt 502S) systems combine proven fire protection, faster installation and simplified specification into one complete solution. Backed by extensive fire testing, local technical support and the FREE Trafalgar System Selector App, Trafalgar FyreBATT 50 (also known as Ryanbatt 502S) is an industry-leading and cost-effective solution for structural penetrations, providing numerous WRAP FREE approvals, saving time and costs on labour. Check out our technical manual for all approvals.

icons to show benefits of FyreBATT 50 for structural penetrations

Coated on both faces with FyreMASTIC A-R (also known as Ryanmastic), an ablative fire-resistant acrylic, Trafalgar FyrBATT 50 effectively prevents the passage of hot gases and flames, reduces heat transfer, and maintains fire compartmentation for up to 120 minutes. This structural penetration fire batt is designed for sealing around steel beams and timber joists, ensuring that fire resistance of separating elements remains uncompromised.

Trafalgar FyreBATT 50 systems comprise of a 50mm grey coated (non-combustible) high-density fire batt used in conjunction with high-performance fire sealants and the industry-leading service penetration wrap – Trafalgar ServoWrap. ServoWrap is a thin 15mm, non-itchy thermal wrap designed to protect against heat transfer via structural penetrations that penetrate through the Trafalgar FyreBATT 50 system. Trafalgar ServoWrap is a foil faced high-temperature fibreglass matt which significantly reduces the conducting of heat through penetrating services. Trafalgar ServoWrap’s thin nature makes it easier to install around structural penetrations while reducing material waste. Unlike traditional thermal wraps, there’s no need to tape the ends, helping installers complete penetrations faster and with fewer installation steps.

Compliance

Trafalgar FyreBATT 50 (also known as Ryanbatt 502S) systems have been independently tested in IANZ/NATA accredited laboratories to comply with AS1530.4:2014 & AS4072.1:2005, ensuring it meet the industry fire safety standards for sealing of penetrations under the National Construction Code clause C4D15, and S1C2.

Key Features

  • Up to 120-minute fire resistance (FRL) systems – application dependent
  • Trusted for commercial, healthcare, data centre and industrial projects
  • Numerous WRAP FREE approvals
  • Easy to cut, strong batts (non-combustible)
  • Trafalgr FyreBATT 50 can either be friction fit or surface mounted – No need to frame out the penetration for certain applications
  • Easy to retro-fit
  • High thermal and acoustic ratings
  • Mastics enhance fire resistance and limits smoke leakage
  • Trafalgar ServoWrap reduces heat transfer through penetrations
  • Tested to AS1530.4:2014 & AS4072.1:2005

Applications

Trafalgar FyreBATT 50 has been specifically designed to reinstate the fire performance of fire rated walls and floors breached by structural penetrations:

  • Steel beams/purlins
  • Timber beams

This system can be used in a wide range of fire barriers:

  • 1 and 2-hour Plasterboard Walls
  • Concrete Walls and Floors
  • Masonry Walls
  • Cross Laminated Timber (CLT) Walls and Floors

System Components

Trafalgar FyreBATT 50 (also known as Ryanbatt 502S) components are manufactured under strict factory-controlled conditions, providing precise thickness, durability, and consistent fire performance and include:

  • Trafalgar FyreBATT 50 (also known as Ryanbatt 502S) – 50mm thick, 1200x600mm size grey coated (non-combustible) high-density fire batt
  • Trafalgar ServoWrap – 15mm thick, non-itchy, 10m long roll needle-felt high temperature blanket foiled on one side (no need for taping edges)
  • FyreMASTIC A-R (also known as Ryanmastic) – light grey 600ml sausages and 5Kg brush grade pails for sealing the batt edges and service penetrations (low VOC)

Product Specifications

Material High-density rock fibre board
Length 1200mm
Width 600mm
Thickness 50mm
Minimum Order Qty 1

 

NOTE:

For compliant installation, Trafalgar FyreBATT 50 (also known as Ryanbatt 502S) must be used with FyreMASTIC A-R (also known as Ryanmastic) and Trafalgar ServoWrap. The board should be securely fitted around service penetrations, ensuring an airtight, fire-rated barrier. Trafalgar FyreBATT 50 (also known as Ryanbatt 502S) works seamlessly with Trafalgar ServoWrap to enhance fire resistance and limit heat transfer, making it an essential component in structural penetration protection and passive fire protection systems.

In Stock

FyreBATT 50 and ServoWrap - Structural Penetrations Systems Technical Manual

Download

Trafalgar FyreBATT 50 Services Assessment Report FAS 210123

Download

Trafalgar FyreBATT 50 Substrates Assessment Report FAS 200363

Download

MSDS - Trafalgar FyreBATT 50 (also known as Ryanfire Ryanbatt)

Download

MSDS - Trafalgar ServoWrap (also known as Ryanfire Servowrap)

Download

MSDS - FyreMASTIC A-R (also known as Ryanfire Mastic)

Download

MSDS - FyreMASTIC HP-R (also known as Ryanfire HP-X)

Download

For more information, please contact our Technical Team at [email protected] or 1800 888 714.